Simplicity as a Priority – the AED for everyone
Defibrillation is the act of delivering electrical energy to the heart in order to restore a proper heart rhythm. In an emergency situation, such as cardiac arrest, a defibrillator in combination with well-performed chest compressions is the only therapy that can save a patient’s life.
Ready when needed – by lifting the device cover, the FRED PA-1 starts up immediately and guides the rescuer step by step during the entire resuscitation process.
The FRED PA-1 is available either as fully automatic or a semi-automatic device.
In its automatic version, the FRED PA-1 delivers the shock without any action of the rescuer. In its semi-automatic version, the FRED PA-1 prompts the rescuer to deliver the shock by pressing the shock button.
The FRED PA-1 is for all types of patients. Used with adult or children electrodes, the FRED PA-1 automatically recognises the electrode type and adjusts the defibrillation energy accordingly.
Dedicated to public access, the FRED PA-1 has been designed to enable untrained users to save lives.
Easy-to-use AED for responders at all levels
- Ease of use: interface with 1-2-3 steps
- 10 year warranty – providing peace of mind
- Pre-connected electrodes for faster application to the patient’s chest
- 3 year electrode life
- 6 year battery life
- Automatic self-tests for detection of electrode expiration and battery capacity – the FRED PA-1 as well as the Online version indicate their status via LED on the device
- Chest compression assistant:
– Metronome
– (Optional) FreeCPR: feedback on the frequency of the chest compression
FRED PA-1 Videos
Accessories & Storage Items
Click here to view the full product list of accessories and storage items for the FRED PA-1 and Online version.
AED Maintenance
The FRED PA-1 automatically performs regular self-tests and indicates whether or not the device is ready for use.
For more information on maintaining your device, click here.
FRED PA-1 Quiz
Want to test your knowledge on the FRED PA-1? Take our quiz!
Download Brochures
Specifications:
DEFIBRILLATOR | |
Operations: | Fully automatic and semi-automatic versions |
Waveform: | BTE (Biphasic Truncated Exponential) |
Therapy range (J): | AED adult: 150/200/200J – other energies can be configured AED child: 50/50/50J – other energies settings can be configured, automatic adaption when paediatric pads are connected |
Voice prompts: | LED and pictograms with voice prompts to guide the user. |
Customisable: | Voice prompt, CPR settings, and shock protocols via AED Manager |
CPR feedback: | Real-time guidance for CPR rate, metronome for CPR rate |
Visible indicators: | Main status, modem, battery, service, and pad status |
Warranty: | 10 years |
PHYSICAL/ENVIRONMENTAL | |
Dimensions (L x W x D): | 310 x 255 x 100 mm (h x l x w) |
Weight: | 2.5 kg (5.5 lbs), including battery and pads |
Dust/Water resistance: | IP55 |
Operating temperature: | -5°C to +40°C (23°F to +104°F) Transport / storage: -20°C to 50°C |
Humidity: | 30 to 95 % non-condensing Transport / storage: 0 to 95 % non-condensing |
Pressure: | 700 to 1060 hPA Transport / storage: 500 to 1060 hPA |
PADS | |
Type: | For adult and child 2m length 80 cm2 active surface Active surface for child is 42 cm² |
Shelf life: | Adult: 3 years Child: 2 years |
BATTERY lithium battery | |
Life: | 6 years |
Capacity: | More than 140 shocks at maximum energy and 6 hours of operation. If device is stored/used in optimal temperature conditions between 15°C to 25°C |
ELECTRICAL DATE | |
Standby duration: | 6 years with weekly self tests (corresponding to laboratory tests at 25°C) for FRED PA-1 3 years with weekly self tests for FRED PA-1 Online (Corresponding to laboratory tests at 25°C) |
INTERFACE & DATA RECORDING | |
Interface: | SD Card |
Recorded data: | 2 hours ECG signal recording and 500 tech- nical events |